For over 15 years, Fresenius Kabi have designed and implemented numerous training programs tailored to the requirements and needs of each individual customer. This includes various teaching and training techniques to adapt to each learning style.
Each customer is allocated a dedicated team inclusive of; Clinical Account Manager, Business Development Manager and Field Service Engineer who will utilise their own expertise to ensure the process is seamless whilst working in partnership to meet the customer needs.
Agilia® SP TIVA WiFi
Please note: For Healthcare Professional Use Only. For further information on the dosage and mode of administration of any specific medicinal product by means of the Agilia SP TIVA, please refer to the respective currently approved SmPC.
- Filename
- GB-TIVA-2400001 Agilia SP TIVA Data Sheet.pdf
- Size
- 1 MB
- Format
Details
- Clinical service
- Features
- Links
- Presentation and order codes
- Product info
- Software
- Technical data
- Technical service
- Technical specification
• The infusion settings are guided and each step is clearly identified.
• Available modes: TCI, mL/h, and Dose.
• The displayed instructions are simple to follow. Intuitive settings increase user confidence.
Clear monitoring:
• Monitoring is simple because of easily accessible numerical and graphical information.
• The syringe is always visible, and the flow indicator lights enable quick monitoring.
Quick history access:
The graph key provides direct access to TCI information:
• TCI Infusion history in dose and flow rate.
• Key infusion parameters.
• Target and concentration history.
• Wake up time.
By clicking on the links below you will leave the Fresenius Kabi website and be directed to the PubMed National Library of Medicine website.
D. J. Eleveld et al. “Pharmacokinetic-pharmacodynamic model for propofol for broad application in
anaesthesia and sedation.”
Publication in British Journal of Anaesthesia 120 (5): 942-959 (2018)
D. J. Eleveld, J. H. Proost, L. I. Cortínez, A. R. Absalom and M. M. Struys (2014). "A general purpose
pharmacokinetic model for propofol." Anesth Analg 118(6): 1221-1237.
D. J. Eleveld et al. “Target-controlled-infusion models for remifentanil dosing consistent with
approved recommendations.” British Journal of Anaesthesia, 125 (4): 483e491 (2020)
D. J. Eleveld et al. “An Allometric Model of Remifentanil Pharmacokinetics and
Item Code | Description |
Z018930 | Agilia SP TIVA WiFi |
Agilia Connect range:
Basic Profile | Infusion without any display of the drug names and with TCI modes |
Custom Profiles | 19 configurable custom profiles with Vigilant Master Med |
Wireless LAN
Technology | IEEE 802.11 a/b/g/n |
Frequency Band | 2.412 -> 2.472 GHz (2.4 GHz is ISM band) 5.180 -> 5.825 GHz (High Band) |
Modulation | DSSS, CKK, OFDM, MCS7 |
Wireless Security | WPA/WPA2-Entreprise, WPA/WPA2-PSK |
Network Protocols | IPv4 and IPv6 TCP/IP, DHCP, HTTP/HTTPS |
Flow rate range | 0.1 - 1200 mL/h depending on the syringe capacity Flow rate can be restricted for each drug (soft and hard limits) with Vigilant Master Med which is part of a Dose Error Reduction Software |
Flow rate accuracy | +/- 3 % |
Syringes capacities | 5/6, 10/12, 20, 30/35, 50/60 CC Up to 100 different types |
Infusion Modes | Dose rate mode and mL/h mode |
Data log event | 1500 data log events in real time |
Pressure modes | 2 modes available: variable or 3 pre-set levels - Range from 50 to 900 mmHg. (25 mmHg increment from 50 to 250 mmHg / 50 mmHg increment from 250 to 900 mmHg) |
Infusion control | Occlusion pressure pre-alarm, occlusion pressure alarm, end of infusion pre-alarm, end of infusion alarm, volume limit pre-alarm, volume limit alarm, hard and soft flow rate limits, start infusion at pause end |
TCI Mode
Pharmacokinetic models | Drugs | TCI modes | |
---|---|---|---|
Plasma | Effect-site | ||
Eleveld with opioids Eleveld without opioids Modified Marsh | Propofol | ✔ | ✔ |
Schnider | Propofol | ✔ | X |
Katarina Paedfusor Eleveld Minto | Remifentanil | ✔ | X |
Sufentanil Scott | Sufentanil | ✔ | X |
Technical service is an essential component of the Fresenius Kabi MedTech division. At our head office in Runcorn, we have a purpose built, modern and dedicated repair centre which is able to support the growing demand for our devices.
Fresenius Kabi also have a successful and effective apprentice program able to provide the skilled resources required to support all of our business and customer needs. As a business, we want to invest in local people and provide an opportunity to train and provide the key skills required to support our customer needs.
We have a skilled and professional team of Field Service Engineers, working collaboratively with our sales and clinical teams to provide managed solutions to our customers.
Manual pusher | Protection for the ongoing infusion thanks to “Push-Guard” |
Display | Blue graphic LCD monochrome, size 70 mm x 35 mm (256 x 128 pixels) |
Swinglock clamp | Versatile clamp that allows the fixation on a rail or on a pole (Pole: 15-40 mm max. / Rail: 25-35 x 8-10 mm) |
Stackability | Up to 3 devices self-stackable on a pole |
Dimensions (H/W/D) / Weight | 135 x 345 x 170 mm / Approximately 2.1 kg |
Battery | 7.34 V 2.75 Ah - Li-ion Smart battery |
Waterproofness | IP32 |
GB-TIVA-2400006 September 2024